Skip to content

Server Technology PRO4X 36-Outlets PDU

SKU: C4G36RA-2QBE2FE2

Server Technology's PRO4X Switched POPS PDUs run on our state-of-the-art Xerus network interface platform and provide remote access to power, PDU status, input, outlet and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanism to prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched POPS PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions from Legrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.

  • HDOT CX OUTLETS: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • 45 DEGREE ANGLED INFEED: The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
  • NETWORK MONITORING: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
  • MULTI-UNIT LINKING & CASCADING: Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
  • MULTI-COLOR LCD: An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
  • HOT SWAPPABLE CONTROLLER: The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
  • POWER QUALITY MEASUREMENTS: Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
  • RGB LED OUTLET INDICATORS: RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
  • WAVEFORM CAPTURE: Capture voltage and current waveforms automatically or upon demand.
  • ENVIRONMENTAL MONITORING: Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
  • PER-INLET POWER SENSING: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
  • PER-OUTLET POWER SENSING: POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
  • BRANCH CIRCUIT PROTECTION: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
  • OUTLET CONTROL: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.

Call for Availability

Regular price $5,830.45

Shipping calculated at checkout

Details

Server Technology's PRO4X Switched POPS PDUs run on our state-of-the-art Xerus network interface platform and provide remote access to power, PDU status, input, outlet and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanism to prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched POPS PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions from Legrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.

  • HDOT CX OUTLETS: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • 45 DEGREE ANGLED INFEED: The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
  • NETWORK MONITORING: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
  • MULTI-UNIT LINKING & CASCADING: Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
  • MULTI-COLOR LCD: An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
  • HOT SWAPPABLE CONTROLLER: The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
  • POWER QUALITY MEASUREMENTS: Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
  • RGB LED OUTLET INDICATORS: RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
  • WAVEFORM CAPTURE: Capture voltage and current waveforms automatically or upon demand.
  • ENVIRONMENTAL MONITORING: Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
  • PER-INLET POWER SENSING: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
  • PER-OUTLET POWER SENSING: POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
  • BRANCH CIRCUIT PROTECTION: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
  • OUTLET CONTROL: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
Specifications
Environmental Sensors:
Temperature,Humidity,Water,Contact Closure,Air Flow,Differential Pressure
Features:
Multi-color LCD,LCD Display
Input Current:
60 A
Input Voltage:
230 V AC
Limited Warranty:
2 Year
Locking Receptacles:
RamLock Locking Outlet
Management:
  • HTTP/HTTPS
  • TLSv1.2S
  • SHv2
  • Telnet
  • SNMPv2c
  • v3 (GET, SET, Traps)
  • IPv4
  • IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP
Manufacturer:
Legrand Group
Manufacturer Website Address:
http://www.servertech.com
Mount Type:
Rack-mountable
Network (RJ-45):
Yes
Output Voltage:
208 V AC
PDU Type:
Switched
Plug/Connector Type:
IEC 208V/60A 2P+G 6Hr
Power Rating (Watt):
10 kW
Product Series:
PRO4X
Product Type:
PDU
Protection Type:
Branch Circuit,Circuit Protection,Circuit Breaker,Fuse
Receptacle Detail:
12 x IEC 60320 C13,24 x CX
Receptacle Type:
IEC 60320 C13,CX
Remote Outlet Switching:
Yes

LTT PARTNERS

We are a full-service Systems and Solutions Integrator. Through close relationships with dozens of top technology brands, we are the preferred partner for many enterprise organizations and industry leaders.

Learn more
Smiling man on a support team on a virtual call with a headset.

ONGOING SUPPORT

We pride ourselves on building long-term relationships with our partners and clients. From initial consultation to post-installation maintenance, we are always available and happy to help through our support network.

Learn more

Have Questions? We Can Help!

Close (esc)

GET 10% OFF SELECT PRODUCTS!

Enter your email to take advantage of this one time offer.

Age verification

By clicking enter you are verifying that you are old enough to consume alcohol.

Search

Header > Main Menu

Shopping Cart