Server Technology PRO3X 36-Outlets PDU

SKU: C3WG36RL-YCJE2MT3

This all new Server Technology PRO3X Switched POPS PDU features RamLock HDOT outlets running with the Xerus Technology Platform's state of the art network interface module. Server Technology's unique RamLock, a self-locking, elbow-catch mechanism to prevent accidental cord disconnects on standard network power cords. The PDU features HDOT outlets which are dedicated C13 outlets, while the other HDOT Cx outlets can be treated as either a C13 or C19 outlet. This innovative PDU combines input and outlet power monitoring, branch current monitoring and outlet control and supports Legrand plug-and-play sensor types like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more

  • HDOT Cx Outlets:
  • Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • Network Monitoring:
  • Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
  • Multi-Unit Linking & Cascading:
  • Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
  • Multi-Color LCD:
  • An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
  • Hot Swappable Controller:
  • The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
  • RamLock Locking Outlets :
  • A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
  • Environmental Monitoring :
  • Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
  • Per-Inlet Power Sensing :
  • PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
  • Per-Outlet Power Sensing :
  • POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
  • Branch Current Monitoring :
  • Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
  • Branch Circuit Protection:
  • This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
  • Outlet Control :
  • On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
  • High Temperature Rating :
  • This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
  • Flexible Mounting :
  • Includes standard button mounts along with provisions for custom mounting brackets.

Call for Availability

Regular price $3,679.23

Shipping calculated at checkout

Details

This all new Server Technology PRO3X Switched POPS PDU features RamLock HDOT outlets running with the Xerus Technology Platform's state of the art network interface module. Server Technology's unique RamLock, a self-locking, elbow-catch mechanism to prevent accidental cord disconnects on standard network power cords. The PDU features HDOT outlets which are dedicated C13 outlets, while the other HDOT Cx outlets can be treated as either a C13 or C19 outlet. This innovative PDU combines input and outlet power monitoring, branch current monitoring and outlet control and supports Legrand plug-and-play sensor types like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more

  • HDOT Cx Outlets:
  • Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • Network Monitoring:
  • Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
  • Multi-Unit Linking & Cascading:
  • Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
  • Multi-Color LCD:
  • An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
  • Hot Swappable Controller:
  • The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
  • RamLock Locking Outlets :
  • A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
  • Environmental Monitoring :
  • Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
  • Per-Inlet Power Sensing :
  • PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
  • Per-Outlet Power Sensing :
  • POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
  • Branch Current Monitoring :
  • Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
  • Branch Circuit Protection:
  • This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
  • Outlet Control :
  • On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
  • High Temperature Rating :
  • This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
  • Flexible Mounting :
  • Includes standard button mounts along with provisions for custom mounting brackets.
Specifications
Application/Usage:
Data Center
Features:
Multi-color LCD
Input Current:
30 A
Input Frequency:
60 Hz
Input Voltage:
230 V AC
Limited Warranty:
2 Year
Load Capacity (Watt):
8600 W
Locking Receptacles:
HDOT Cx RamLock
Management:
  • HTTP/HTTPS
  • TLSv1.2
  • SSHv2
  • Telnet
  • SNMPv2c
  • v3 (GET, SET, Traps)
  • IPv4
  • IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP
Manufacturer:
Legrand Group
Manufacturer Website Address:
http://www.legrand.us
Maximum Operating Temperature:
140°F (60°C)
Maximum Storage Temperature:
185°F (85°C)
Minimum Operating Temperature:
32°F (0°C)
Minimum Storage Temperature:
-40°F (-40°C)
Mount Type:
Button Mount
Network (RJ-45):
Yes
Output Voltage:
208 V AC
Package Contents:
  • PRO3X 36-Outlets PDU
  • Standard Button Mounts
PDU Type:
Switched
Plug/Connector Type:
NEMA L21-30P
Product Series:
PRO3X
Product Type:
PDU
Protection Type:
Branch Circuit,Circuit Protection,Fuse
Receptacle Detail:
18 x IEC 60320 C13,18 x CX
Receptacle Type:
IEC 60320 C13,CX
TAA Compliant:
Yes
UL Listed:
Yes

LTT PARTNERS

We are a full-service Systems and Solutions Integrator. Through close relationships with dozens of top technology brands, we are the preferred partner for many enterprise organizations and industry leaders.

Learn more
Smiling man on a support team on a virtual call with a headset.

ONGOING SUPPORT

We pride ourselves on building long-term relationships with our partners and clients. From initial consultation to post-installation maintenance, we are always available and happy to help through our support network.

Learn more

Have Questions? We Can Help!

Close (esc)

GET 10% OFF SELECT PRODUCTS!

Enter your email to take advantage of this one time offer.

Age verification

By clicking enter you are verifying that you are old enough to consume alcohol.

Search

Header > Main Menu

Shopping Cart