{"product_id":"avigilon-alta-sys-4ent-dve1-4-door-smart-hub","title":"Avigilon Alta SYS-4ENT-DVE1 4-Door Smart Hub","description":"\u003c!--DROPDOWN TITLE--\u003e\n\u003ch5\u003eProduct Specifications\u003c\/h5\u003e\n\u003c!--DROPDOWN TITLE END--\u003e \u003c!--DROPDOWN PRODUCT SPEC TITLE--\u003e\n\u003cp class=\"ps_title\"\u003eSystem\u003c\/p\u003e\n\u003c!--DROPDOWN PRODUCT SPEC TITLE END--\u003e \u003c!--PRODUCT SPECS TABLE--\u003e\n\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eAccess Control\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003eUp to 4 Avigilon Smart Readers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eDoor Relays\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e4 relays, 5A @ 24VDC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eAuxiliary Relays\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e2 relays, 1A @ 24VDC\u003cbr\u003e2 auxiliary relays and 4 configurable auxiliary I\/O pins provide extra inputs and outputs, and allow additional sensors or Wiegand devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eAvigilon Readers\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003eUp to 4 Avigilon Smart Readers\u003cbr\u003eUses industry standard RS-485 signaling to communicate with Avigilon readers over standard wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e10\/100\/1000 baseT Ethernet; USB port\u003cbr\u003eTLS 1.2+ encryption between Access Control Core and access control cloud service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eREX and Contact Sensors\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e4 REX and 4 contact sensor inputs with EOL monitoring, nominal 5VDC, 1kohm to each input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eAuxiliary I\/O\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e4 input\/output lines with EOL monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003eFPV4: 24V @ 3A or 12V @ 4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eBackup Battery\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003eUse two 12VDC sealed lead acid (SLA) or gel cell batteries in series (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003e\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- CONTENT READ MORE --\u003e\n\n\u003cinput id=\"ch\" type=\"checkbox\"\u003e\n  \u003cspan class=\"content\"\u003e\n\u003c!-- CONTENT READ MORE --\u003e\n\n\u003cp class=\"ps_title\"\u003eMechanical\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003eHeight: 20 in (508 mm)\u003cbr\u003eWidth: 16 in (406.4 mm)\u003cbr\u003eDepth: 4.72 in (119.9 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e10 lbs (4.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003eLifeSafety Power® E1 enclosure pre-installed with 24V FPV4 Power Supply, C4 Relay Based Lock Control Module, and B100 Secondary Voltage Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eWiring\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003eUses RS-485 wiring to connect to the Avigilon Smart Readers\u003cbr\u003eEOL monitoring with single or double termination on all REX, Contact, and Auxiliary inputs supported with user-installed 1k resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp class=\"ps_title\"\u003eEnvironmental\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e5% to 85% relative, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp class=\"ps_title\"\u003eRegulatory\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eCertifications\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003eCE (Europe), IC (Canada), FCC (United States), NOM (Mexico), RCM (Australia, New Zealand), RoHS, UKCA (United Kingdom), ANATEL (Brazil), UL 294\u003cbr\u003ePerformance Levels: Attack Level I, Endurance Level I, Line Security Level I, Standby Power Level I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003eLifetime limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp class=\"ps_title\"\u003eElectrical\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e120VAC, 208\/230VAC with cuttable jumper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eInput Current\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e1.8Amp max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e12VDC and 24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"title\"\u003eOperating Current\u003c\/td\u003e\n\u003ctd class=\"desc\"\u003e2.2A @ 12V with 4 Avigilon Smart Readers\u003cbr\u003e1.2A @ 24V with 4 Avigilon Smart Readers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp class=\"reference\"\u003e\u003c\/p\u003e\n\n\u003clabel class=\"viewlinks\" for=\"ch\"\u003eView less ↑\u003c\/label\u003e\n    \n\n\u003clabel class=\"viewlinks\" for=\"ch\"\u003eView more \u0026gt;\u003c\/label\u003e\n\n\n\n\u003c!--DROPDOWN TITLE--\u003e\n\u003ch5\u003eProduct Resources\u003c\/h5\u003e\n\u003c!--DROPDOWN TITLE END--\u003e \u003c!--DROPDOWN PRODUCT SPEC TITLE--\u003e\n\u003cspan class=\"pbtnWrap\"\u003e\n\u003ca href=\"https:\/\/docs.avigilon.com\/bundle\/avigilon-1224v-4door-smart-hub-datasheet\/resource\/avigilon-1224v-4door-smart-hub-datasheet.pdf\" target=\"_blank\" class=\"pbtn\"\u003eProduct Datasheet\u003c\/a\u003e\n  \u003c\/span\u003e\n\u003c!--DROPDOWN PRODUCT SPEC TITLE END--\u003e\u003c\/span\u003e","brand":"Avigilon","offers":[{"title":"Default Title","offer_id":46269647847609,"sku":"SYS-4ENT-DVE1","price":1780.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0274\/4490\/4014\/files\/Avigilon-Alta-SYS-4ENT-DVE1-4-Door-Smart-Hub-Shut.png?v=1770067858","url":"https:\/\/www.lttpartners.com\/products\/avigilon-alta-sys-4ent-dve1-4-door-smart-hub","provider":"LTT Partners","version":"1.0","type":"link"}